Figure 3 · point file

eFEDS negligible-SWCX scenario:数据点推理

eFEDS negligible-SWCX scenario: point reasoning

ponti2023_efeds_negligible_swcx

G. Ponti et al. (2023) study file

Figure 3最终值

Final Figure 3 value

0.4065102010.406510201 – 0.40651020110−15 erg cm−2 s−1 arcmin−2

固定SWCX scenario;不是central estimate或CI。

A fixed SWCX scenario, not a central estimate or confidence interval.

原文输入量

Native published input

Table 4 negligible-SWCX CGM flux:24.1(0.3-0.6)+5.6(0.6-2.0)。

Table 4 negligible-SWCX CGM flux: 24.1 (0.3-0.6) plus 5.6 (0.6-2.0).

转换链

Conversion chain

用published kT/Z模型截取0.5-0.6 soft-bin fraction,再加0.6-2.0。

Use the published kT/Z model to retain the 0.5-0.6 fraction of the soft bin, then add 0.6-2.0.

  1. 固定当前Table 4 SWCX scenario,读取该scenario的CGM 0.3--0.6与0.6--2.0 flux;两个scenario不合并。Fix the relevant Table 4 SWCX scenario and read its CGM 0.3--0.6 and 0.6--2.0 fluxes; never combine the two scenarios.
  2. 用该scenario published kT/Z的Lodders APEC,并对disnht lognormal N_H distribution做quadrature,求0.5--0.6占published 0.3--0.6 flux的fraction。Use the scenario's published kT/Z Lodders APEC model and quadrature over the disnht lognormal N_H distribution to obtain the 0.5--0.6 fraction of the published 0.3--0.6 flux.F_0.5-2 = F_0.6-2 + f_0.5-0.6|0.3-0.6 × F_0.3-0.6
  3. 把Table 4的10^-13 erg cm^-2 s^-1 deg^-2结果除以3600并换成Figure 3的10^-15 arcmin^-2单位;保留为fixed point。Divide the Table 4 result in 10^-13 erg cm^-2 s^-1 deg^-2 by 3600 and convert to the Figure 3 10^-15 arcmin^-2 unit; retain it as one fixed point.S_fig = F_0.5-2 × 100 / 3600

新增假设与边界

Added assumptions and boundaries

Provenance

DOI: 10.1051/0004-6361/202243992

figure3_reference_registry.json · frozen Figure 3 ledger